Geo Saver D Defibrillator
The geolocalised AED goes beyond
Semi-Automatic AED with ECG Monitoring.
It allows the user to view the ECG and everything needed to know about the patient and ongoing rescue treatment on a 5.7″ full-colour display compliant to IEC/EN 60601-2-27.
€1,762.94€2,646.09
Shipping 1-2 Business Days
Trading for over 25 Years
ECG can also be sent in real time to the AMISAVERCLOUD PLATFORM to enable another operator to monitor the ECG simultaneously with the local rescuer.
About Device:
A battery gauge with residual capacity the indicator of available memory for recording a notice if the microphone is active or OFF the local date and time, alarms.
About Rescue:
- The adult or child protocol in use
- The modality in use (AED, ECG or Manual)
- The fibrillation and shock counts
- The elapsed rescue time
- The heart rate (bpm)
- The impedance (ohms)
- The energy level to be delivered (joule)
- A touch/not touch pictogram
- ECG waveform
- The R wave detection in Manual Synchronous
- A charging bar graph if device charges
- A CPR bar graph and cycles countdown
Model Numbers: | |
Code SVD-B004: | Standard Version maximum energy at 200J |
Code SVD-B005: | Power Version with maximum energy at 360J |
Configuration Options: | |
Conf-Norm: Standard Basic Configuration | (adult pads, disposable battery, carrying case) |
Conf-Rech: Rechargeable Configuration | (adult pads, accumulator, charger station, carrying case) |
Conf-Print: Print Ready Configuration | (adult pads, disposable battery, carrying case, IrDa port and thermal printer) |
Conf-Rech/Print: Rechargeable & Print Ready Configuration | (adult pads, accumulator, charger station, carrying case, IrDA port and thermal printer) |
Technical Data: | |
Operation: | AED Semi-Automatic; ECG Monitoring capability |
Energies: | Standard max 200J or Power max 360J |
Waveform: | Adaptive BTE (biphasic truncated exponential) conforming to patient chest’s impedance |
Protocols: | Various adult shock protocols available on request |
Factory default: | Adult Standard escalating 150, 200, 200J Adult Power escalating 200, 250, 360J Pediatric (Standard or Power) 50J fixed |
Charging time: | ≤9 seconds with a new and fully charged battery depleted battery will result in a longer charging time |
Analysis time: | IEC/EN 60601-2-4 from 4 to 15 seconds |
Impedance: | 20-200 ohms |
Sensitivity: | IEC/EN 60601-2-4 (AHADB, MITDB source), 97% |
Specificity: | IEC/EN 60601-2-4 (AHADB, MITDB source), 99% |
Controls: | 2 buttons: ON/OFF, shock button, and 3 buttons to surf the menu. |
Indicators: | Status LED indicator informing on device condition Battery gauge with remaining capacity rate Audible alerts and text display with service alarms |
Upgradeable: | through a USB cable or memory card or by remote through AMISAVERCLOUD |
ECG Monitoring: |
|
Operations: | Through defibrillation pads or standard ECG electrodes attached to a separate 2-Lead patient monitoring reusable cable SAV-C0017 |
ECG size: | Manual setting through the menu |
Heart Rate: | 30-200 bpm |
Sweep Speed: | 25 mm/sec |
Standards: | IEC/EN 60601-2-27 less then the points 202.6.2.101; 201.12.1.101.12,13; 208.6.6.2.101 not performed for the intended use of the device, as it is not intended for environments such as operating theatres or intensive care units |
Display: | 5,7” TFT colour, 640 x 480 pixel |
Battery Options: | |
Type: | Li-SOCl2 Disposable, code SAV-C1032 |
Autonomy: | 250 complete rescue cycles (shocks at 200J and CPR) or 160 complete rescue cycles (shocks at 360J and CPR) or 24 hours ECG analysis for a new and fully charged battery (*) |
Shelf-Life: | when stored in original packaging 5 years (*) |
Battery-Life: | 4 years once installed to AED, assuming one battery insertion test and daily self-test but without switching AED on (*) |
Type: | Li-ion Accumulator, code SAV-C1033 |
Recharging time: | 2,5 hours with the charger station code SAV-C1034 (*) (recommended to charge every 4 months at least) |
Autonomy: | 200 shocks at 200J or 110 shocks at 360J or 14 hours in ECG Monitoring for a new fully charged accumulator (*) |
Battery-Life: | 2 years or 300 charging cycles (*) |
Pads Options: | |
Type: | Disposable, pre-gelled and self-adhesive |
Adult: | Code SAV-C0846, for patient >8 years or >25 kg |
Pediatric: | Code SAV-C0016, for patient <8 years or <25 kg |
Cable length: | 120 cm |
Shelf-Life: | 30 months |
Event Recording: | |
Internal memory: | up to 6 continuous hours of ECG and rescue events |
Optional memory: | Removable SD card; length of storage depends on card capacity: a 2GB card records up to 100 hours |
Data recording: | “AED1LOG“ text file with detailed self-test activity “AEDFILES“ multimedia files with complete recorded information |
Event review: | “Saver View Express“ data manager software |
Physical: | |
Size: | 29,5 x 23 x 11,5 cm |
Weight: | +/- 2,85 Kg |
Environmental: | |
Operating temperature: | 0°C to 55°C (32°F TO 131°F) |
Storing/Shipping temperature: | -40°C to 70°C (-40°F TO 158°F) without battery |
Humidity: | 10% to 95% relative humidity non condensing |
Sealing (IP Protection): | IEC/EN 60529 class IP56; splash proof, dust protected |
Shock/Drop Abuse Endurance: | IEC/EN 60601-1 clause 21; 1 meter drop, impact, force, rough handling, mobile tolerance |
Electrostatic Discharge: | IEC/EN 61000-4-2 |
Electromagnetic Compatibility: | IEC/EN 60601-1-2 Emission, Immunity |
Electrical Protection: | IEC/EN 60601-1; Internally Powered, Type BF |
Directive 93/42/CEE and 2007/47/CE: | Class IIb |
Geoloc Module: | |
Frequency: | GSM: 850, 900, 1800, 1900 MHz; UMTS: 900, 2100 MHz; GPS: 1575, 1600 MHz |
Geoloc Battery Options: | |
Type: | Li-SOCl2 Disposable, code SAV-C1038 |
Shelf-Life: | when stored in original packaging 5 years (*) |
Battery-Life: | 4 years once installed to AED, assuming one battery insertion test and daily self-test but without switching AED on (*) |
Type: | Li-ion Accumulator, code SAV-C1039 |
Recharging time: | 2,5 hours with the charger station code SAV-C1040 (*) (recommended to charge every 4 months at least) |
Battery-Life: | 2 years or 300 charging cycles (*) |
(*)Temperature at 20°C Humidity 45% non-condensing |
A drone system that delivers Automated External Defibrillators (AEDs) to the scene of cardiac arrests. In doing so, bystanders will now have the ability to initiate life-saving measures while awaiting professional medical care. Out-of-hospital cardiac arrests affect some 275,000 individuals in Europe each year and carry a low survival rate of about 10%.
Research suggests when CPR and early defibrillation is initiated within the first few minutes the survival rate could potentially increase to as much as 70%.
- Hibernia Medical does not supply goods on a sale or return basis.
- Hibernia Medical does not accept the return of goods without prior written communication to the Customer Service department.
- Goods can be returned once approval in writing has been given by Hibernia Medical.
- A ‘Goods Return Form’ must be completed for all returns. Notification of the intent to return Goods must be made within 14 days of the Delivery/Invoice date.
- The only goods that will accepted for refund must be a current stock line and not a discontinued line, nonreturnable product or a special-order item.
- All approved goods for return must be in perfect condition, in original packaging, sellable and be completely without defect or damage. Such damage will totally cancel any obligation by Hibernia Medical for any refund whatsoever on the item.
- Electrical and photographic equipment will only be accepted if complete with all leads, accessories and software. Any software must have its original seal intact.
- Goods are returned at the sender’s responsibility and cost. Hibernia Medical accepts no responsibility for goods lost or damaged during return transit. We recommend that the returned item(s) to our office are registered/tracked. Additionally, Hibernia Medical does not refund return carriage, postage fees or insurance costs.
- Please check the package and label before opening any products to ensure that you have received the correct items. Shipment errors must be reported no later than seven (7) days after the invoice date.
- Non-stock items and special-order items are subject to a no-return policy.
- All sales of clearance items are final and we cannot accept returns.
Please Note: Special order items and discontinued items are not subject to this returns policy and will be dealt with on a case-by-case basis.
All items returned are subject to a restocking fee of 10%.
Items returned after 14 days are liable to additional handling charges:
- 14 – 21 days old 15% of invoice value or minimum of €20.00
- 21 – 30 days old 20% of invoice value or minimum of €20.00
- 31 – 60 days old 25% of invoice value or minimum of €20.00
- Returns after 60 days are dealt with on a case-by-case basis
If you return part or all of your order, we will not refund the delivery charge as this part of our service to you has been completed. In the cases of incorrect, damaged or faulty goods, the delivery charge for a replacement to be sent out will not be charged.
For returns/refunds requests within 14 days please contact our Customer Service Team on 01 8665727 or email sales@hiberniamedical.ie
If you’ve asked for a refund, we will credit the account you used to pay for your order. Please allow up to 14 days for the refund to appear on your account.
Our Address:
Hibernia Medical
E3 Calmount Business Park
Ballymount
Dublin 12
D12 NA40
You May Also Like
You may also like…
-
AED Defibrillators & Accessories
Savepads Electrodes| Selfadhesive| 1 Pair
€77.79ex VAT€77.79inc VAT

Bosch

Littmann

Saver One

Omron

Omron

Iem

Braun

and

riester

mesi

medi Plent

sono site

wench allyn

plinth medical