Cobas H 232 POC System (Roche)
Used to support cardiac decisions with rapid and easy determination of cardiac biomarkers such as: troponin T, NT–proBNP, D–dimer, CK–MB and myoglobin.
• Cardiac markers in 12 minutes
• Standardised results with central lab
€2,308.95 – €2,518.95
Shipping 1-2 Business Days
Trading for over 25 Years
Roche Cobas H 232 POC System
On-the-spot care & share
For Frontline Healthcare Providers, cobas h 232 POC system is a portable point-of-care system that supports optimized treatment of patients with symptoms of chest pain and dyspnea, because it enables confident on-the-spot diagnosis and assessment of the patient’s condition based on objective results, comparable with Roche laboratory methods, that can be shared wirelessly for immediate feedback and response.
Benefits
The ideal fit for “on-the-spot care and share” in pre-hospital settings and emergency rooms settings
Fast
On-the-spot results are available in 3 steps and 12 minutes or less1,2,3,4,5
Portable
Handheld point of care system is lightweight and easy to use, even in mobile situation6
Connected
Wireless technology ensures immediate availability of results at all Points of Care (requires cobas® POC IT solution)6
Confident
Accurate results, standardized with Roche central laboratory tests7
Safety
- Operator ID entry and lockout to ensure use by authorized staff
- Patient and user ID to ensure correct documentation of test results
- Quality control lockout
Control and traceability
- Enhanced connectivity through wireless technology and a unique QR code feature can minimize errors, increase safety and a streamline workflow
- Connection to the cobas®POC IT solution allows extension of the testing network and ensures control of operators and quality assurance from the central laboratory
- Automatic recertification of operators through cobas academy to ensure use by trained operators only.
The cobas h 232 meter is an instrument for the quantitative evaluation of immunoassays using the gold-labeling technique. The rapid diagnostic tests in strip format available for this meter support efficient diagnosis and assessment of cardiovascular diseases. The evaluation of these tests with the cobas h 232 meter combines the advantages of a rapid diagnosis with enhanced clinical interpretation of quantitative values (in comparison with qualitative tests). In addition, automated evaluation provides more reliable results by eliminating the potential sources of error associated with visual reading. Refer to the package inserts accompanying the test strips for detailed information on specific tests.
Readings may be carried out directly where the blood samples are taken. Therefore, the cobas h 232 meter is ideal for use at the point of care in emergency rooms, intensive care units and ambulances, as well as by cardiologists and general practitioners. The cobas h 232 meter is rapid and easy to operate: Insert an unused strip in the meter and apply the sample. After the reaction period, the meter provides a quantitative result; in addition, a qualitative result is provided prior to the end of some tests.
The cobas h 232 meter has the ability to connect to a data management system (DMS) by means of wireless communication (if the meter is equipped with WLAN functionality) or through the Handheld Base Unit from Roche Diagnostics (available separately). This price of medical equipment (cobas h 232 meter) supports data exchange via the POCT1A standard. Data management systems may have the ability to expand the security features of the meter, such as enabling operator lockouts. Data management systems may also enable data transfer to an LIS or HIS. Refer to the manuals of the Handheld Base Unit and of your DMS for technical details.
Available Tests
The cobas h 232 POC system allows rapid and easy determination of Troponin T, NT-proBNP, D-Dimer, CK-MB and Myoglobin in different settings, like ambulances, general practitioner offices and emergency rooms.
TEST | MEASURING RANGE | TIME TO RESULT | CLINICAL UTILITY |
---|---|---|---|
Troponin | 40 – 2,000 ng/L | 12 min | Early aid in diagnosis of acute myocardial infarction and identification of patients with an elevated mortality risk4 |
NT-proBNP | 60 – 9,000 pg/mL | 12 min | Aid in diagnosis of patients with suspected heart failure, in monitoring of patients with compensated left ventricular dysfunction and in the risk stratification of patients with acute coronary syndromes5 |
CK-MB | 1.0 – 40 ng/mL | 12 min | Aid in diagnosis of patients with suspected acute myocardial infarction (AMI, heart attack), assessment of the size of the infarction and detection of re-infarction1 |
D-Dimer | 0.1 – 4.0 µg/mL | 8 min | Aid in exclusion of deep venous thrombosis and pulmonary embolism2 |
Myoglobin | 30 – 700 ng/mL | 8 min | Aid in diagnosis of patients with suspected myocardial infarction, reperfusion control3 |
Related Documents:
- Hibernia Medical does not supply goods on a sale or return basis.
- Hibernia Medical does not accept the return of goods without prior written communication to the Customer Service department.
- Goods can be returned once approval in writing has been given by Hibernia Medical.
- A ‘Goods Return Form’ must be completed for all returns. Notification of the intent to return Goods must be made within 14 days of the Delivery/Invoice date.
- The only goods that will accepted for refund must be a current stock line and not a discontinued line, nonreturnable product or a special-order item.
- All approved goods for return must be in perfect condition, in original packaging, sellable and be completely without defect or damage. Such damage will totally cancel any obligation by Hibernia Medical for any refund whatsoever on the item.
- Electrical and photographic equipment will only be accepted if complete with all leads, accessories and software. Any software must have its original seal intact.
- Goods are returned at the sender’s responsibility and cost. Hibernia Medical accepts no responsibility for goods lost or damaged during return transit. We recommend that the returned item(s) to our office are registered/tracked. Additionally, Hibernia Medical does not refund return carriage, postage fees or insurance costs.
- Please check the package and label before opening any products to ensure that you have received the correct items. Shipment errors must be reported no later than seven (7) days after the invoice date.
- Non-stock items and special-order items are subject to a no-return policy.
- All sales of clearance items are final and we cannot accept returns.
Please Note: Special order items and discontinued items are not subject to this returns policy and will be dealt with on a case-by-case basis.
All items returned are subject to a restocking fee of 10%.
Items returned after 14 days are liable to additional handling charges:
- 14 – 21 days old 15% of invoice value or minimum of €20.00
- 21 – 30 days old 20% of invoice value or minimum of €20.00
- 31 – 60 days old 25% of invoice value or minimum of €20.00
- Returns after 60 days are dealt with on a case-by-case basis
If you return part or all of your order, we will not refund the delivery charge as this part of our service to you has been completed. In the cases of incorrect, damaged or faulty goods, the delivery charge for a replacement to be sent out will not be charged.
For returns/refunds requests within 14 days please contact our Customer Service Team on 01 8665727 or email [email protected]
If you’ve asked for a refund, we will credit the account you used to pay for your order. Please allow up to 14 days for the refund to appear on your account.
Our Address:
Hibernia Medical
E3 Calmount Business Park
Ballymount
Dublin 12
D12 NA40
You May Also Like
Bosch
Littmann
Saver One
Omron
Omron
Iem
Braun
and
riester
mesi
medi Plent
sono site
wench allyn
plinth medical