Saver One D Semi-Automatic AED with ECG Monitoring
While in AED mode, it allows the user to view the ECG and everything needed to know about the patient and ongoing rescue treatment on a very large full-colour display (12×8 cm).
It can be switched in a ECG Monitoring mode, to allow for watch over the rhythm and heart rate while using defibrillation pads or standard ECG electrodes connected to a separate cable.
€1,540.00
Shipping 1-2 Business Days
Trading for over 25 Years
The AED goes beyond
- Semi automatic AED with ECG monitoring for paramedics and trained responders!
- Rugged, small and lightweight AED with ECG Monitoring capability.
- Totally reliable for trained users featuring advanced capacities to help improve lifesaving outcomes.
Meet AHA/ERC 2017 Guidelines
- Maintenance-Free: Automatically performs daily, monthly and six-month extensive self-checks of all main components: battery, internal electronics, energy charge and disarm, shock and ECG calibration systems. Daily testing data are stored by the device as text file (named AED1LOG) easily readable by any computer. AED runs further tests after each battery insertion as well as every time the device is turned on. A visual cue (green/red status indicator) provides effective alert to users whether AED is in working order and ready for a rescue. Service Mini-Screen: In standby the mini LCD screen displays a check mark confirming AED is ready for use and a battery gauge informing about the residual charge. Error codes will appear in faulty conditions.
- Helpful Menu: 3 buttons for navigating the software menu to set up device at user leisure: adjust the local date or time, adapt the screen or volume to ambient lights and noises, exclude the microphone while recording events, select a different language, print out the ECG files or simply get information on device and battery.
- CPR Coaching: More instructive voice and text prompts guide user through rescue. A built-in metronome assists responder during the CPR providing audio cues for the appropriate number and rate of chest compressions.
- Adult / Child Capability: Can be used on patients of any age with Adult or Pediatric proper electrodes. Device senses when Pediatric pads are installed and automatically adjusts to use a more appropriate lower energy level (50J).
- Monitoring section menu: a new section has been introduced for the management of technical and physiological alarms and signals, according to IEC/EN 60601-2-27: patient loss, high or low heart rate, audio and visual signal for detection of a shockable rhythm so that the operator can switch/activate the semi-automatic modes to deliver the shock (using the appropriate pads); scaling of the ECG trace on the display (gain x2 or ÷2) reset of the audio or visual alarms.
The Right Choice For Harsh, Outdoor Or Mobile Use
While in AED mode, it allows the user to view the ECG and everything needed to know about the patient and ongoing rescue treatment on a very large full-colour interactive display (12×8 cm).
It can be switched in a ECG Monitoring mode, to allow for watch over the rhythm and heart rate while using defibrillation pads or standard ECG electrodes connected to a separate cable.
5.7” TFT Colour Display with the most detailed and comprehensive screen provides valuable information to rescuers:
About Device:
• a battery gauge with residual capacity
• the indicator of available memory for recording
• a notice if the microphone is active or OFF
• the local date and time, alarms.
About Rescue:
• the adult or child protocol in use
• the modality in use (AED, ECG or Manual)
• the fibrillation and shock counts
• the elapsed rescue time
• the heart rate (bpm)
• the impedance (ohms)
• the energy level to be delivered (joule)
• a touch/not touch pictogram
• ECG waveform
• the R wave detection in Manual Synchronous
• a charging bar graph if device charges
• a CPR bar graph and cycles countdown
Related Documents
Technical Specifications
While in AED mode, it allows the user to view the ECG and everything needed to know about the patient and ongoing rescue treatment on a very large full-colour interactive display (12×8 cm). It can be switched in a ECG Monitoring mode, to allow for watch over the rhythm and heart rate while using defibrillation pads or standard ECG electrodes connected to a separate cable.
DEFIBRILLATOR | |
Operation: | AED Semi-Automatic; ECG Monitoring capability |
Energies: | Standard max 200J or Power max 360J |
Waveform: | Adaptive BTE (biphasic truncated exponential) conforming to patient chest’s impedance |
Protocols: | Various adult shock protocols available on request |
Factory default: | Adult Standard escalating 150, 200, 200J Adult Power escalating 200, 250, 360J Pediatric (Standard or Power) 50J fixed |
Charging time: | ≤9 seconds with a new and fully charged battery depleted battery will result in a longer charging time |
Analysis time: | IEC/EN 60601-2-4 from 4 to 15 seconds |
Impedance: | 20-200 ohms |
Sensitivity: | IEC/EN 60601-2-4 (AHADB, MITDB source), 97% |
Specificity: | IEC/EN 60601-2-4 (AHADB, MITDB source), 99% |
Controls: | 2 buttons: ON/OFF, shock button, and 3 buttons to surf the menu. |
Indicators: | Status LED indicator informing on device condition Battery gauge with remaining capacity rate Audible alerts and text display with service alarms |
Upgradeable: | through a USB cable or memory card |
ECG MONITORING |
|
Operations: | Through defibrillation pads or standard ECG electrodes attached to a separate 2-Lead patient monitoring reusable cable SAV-C0017 |
ECG size: | Manual setting through the menu |
Heart Rate: | 30-200 bpm |
Sweep Speed: | 25 mm/sec |
Standards: | IEC/EN 60601-2-27 less then the points 202.6.2.101; 201.12.1.101.12,13; 208.6.6.2.101 not performed for the intended use of the device, as it is not intended for environments such as operating theatres or intensive care units |
Display: | 5,7” TFT colour, 640 x 480 pixel |
BATTERY OPTIONS | |
Type: | Li-SOCl2 Disposable, code SAV-C0903 |
Autonomy: | 250 complete rescue cycles (shocks at 200J and CPR) or 160 complete rescue cycles (shocks at 360J and CPR) or 24 hours ECG analysis for a new and fully charged battery (*) |
Shelf-Life: | when stored in original packaging 5 years (*) |
Battery-Life: | 4 years once installed to AED, assuming one battery insertion test and daily self-test but without switching AED on (*) |
Type: | Li-ion Accumulator, code SAV-C0011 |
Recharging time: | 2,5 hours with the charger station code SAV-C0014 (*) (recommended to charge every 4 months at least) |
Autonomy: | 200 shocks at 200J or 110 shocks at 360J or 14 hours in ECG Monitoring for a new fully charged accumulator (*) |
Battery-Life: | 2 years or 300 charging cycles (*) |
PADS OPTIONS | |
Type: | Disposable, pre-gelled and self-adhesive |
Adult: | Code SAV-C0846, for patient >8 years or >25 kg |
Pediatric: | Code SAV-C0016, for patient <8 years or <25 kg |
Cable lenght: | 120 cm |
Shelf-Life: | 30 months |
EVENT RECORDING | |
Internal memory: | up to 6 continuous hours of ECG and rescue events |
Optional memory: | Removable SD card; lenght of storage depends on card capacity: a 2GB card records up to 100 hours |
Data recording: | “AED1LOG“ text file with detailed self-test activity “AEDFILES“ with complete recorded information |
Event review: | “Saver View Express“ data manager software |
PHYSICAL | |
Size: | 26,5 x 21,5 x 7,5 cm |
Weight: | 2,08 kg with disposable battery 2,13 kg with rechargeable battery |
ENVIROMENTAL | |
Operating temperature: | 0°C to 55°C (32°F TO 131°F) |
Storing/Shipping temperature: | -40°C to 70°C (-40°F TO 158°F) without battery |
Humidity: | 10% to 95% relative humidity non condensing |
Sealing (IP Protection): | IEC/EN 60529 class IP54; splash proof, dust protected |
Shock/Drop Abuse Endurance: | IEC/EN 60601-1 clause 21; 1 meter drop, impact, force, rough handling, mobile tolerance |
Electrostatic Discharge: | IEC/EN 61000-4-2 |
Electromagnetic Compatibility: | IEC/EN 60601-1-2 Emission, Immunity |
Electrical Protection: | IEC/EN 60601-1; Internally Powered, Type BF/CF |
Directive93/42/CEE and 2007/47/CE: | Class IIb |
(*)Temperature at 20°C Humidity 45% non-condensing |
Related Documents:
- Hibernia Medical does not supply goods on a sale or return basis.
- Hibernia Medical does not accept the return of goods without prior written communication to the Customer Service department.
- Goods can be returned once approval in writing has been given by Hibernia Medical.
- A ‘Goods Return Form’ must be completed for all returns. Notification of the intent to return Goods must be made within 14 days of the Delivery/Invoice date.
- The only goods that will accepted for refund must be a current stock line and not a discontinued line, nonreturnable product or a special-order item.
- All approved goods for return must be in perfect condition, in original packaging, sellable and be completely without defect or damage. Such damage will totally cancel any obligation by Hibernia Medical for any refund whatsoever on the item.
- Electrical and photographic equipment will only be accepted if complete with all leads, accessories and software. Any software must have its original seal intact.
- Goods are returned at the sender’s responsibility and cost. Hibernia Medical accepts no responsibility for goods lost or damaged during return transit. We recommend that the returned item(s) to our office are registered/tracked. Additionally, Hibernia Medical does not refund return carriage, postage fees or insurance costs.
- Please check the package and label before opening any products to ensure that you have received the correct items. Shipment errors must be reported no later than seven (7) days after the invoice date.
- Non-stock items and special-order items are subject to a no-return policy.
- All sales of clearance items are final and we cannot accept returns.
Please Note: Special order items and discontinued items are not subject to this returns policy and will be dealt with on a case-by-case basis.
All items returned are subject to a restocking fee of 10%.
Items returned after 14 days are liable to additional handling charges:
- 14 – 21 days old 15% of invoice value or minimum of €20.00
- 21 – 30 days old 20% of invoice value or minimum of €20.00
- 31 – 60 days old 25% of invoice value or minimum of €20.00
- Returns after 60 days are dealt with on a case-by-case basis
If you return part or all of your order, we will not refund the delivery charge as this part of our service to you has been completed. In the cases of incorrect, damaged or faulty goods, the delivery charge for a replacement to be sent out will not be charged.
For returns/refunds requests within 14 days please contact our Customer Service Team on 01 8665727 or email [email protected]
If you’ve asked for a refund, we will credit the account you used to pay for your order. Please allow up to 14 days for the refund to appear on your account.
Our Address:
Hibernia Medical
E3 Calmount Business Park
Ballymount
Dublin 12
D12 NA40
You May Also Like
You may also like…
-
AED Defibrillators & Accessories
Smarty Saver Disposable, Universal, Preconnected Standard PADs
€57.13ex VAT€57.13inc VAT -
AED Defibrillators & Accessories
Smarty Saver Disposable, Universal, Preconnected, Smart PADs
€71.40ex VAT€71.40inc VAT
Bosch
Littmann
Saver One
Omron
Omron
Iem
Braun
and
riester
mesi
medi Plent
sono site
wench allyn
plinth medical